PN 154-631-2 www.cascademicrotech.com InfinityQuad Probe PAD Layout Rules • 3
Table 3. Available pitch and the recommended maximum operational frequency.
Rule 103: Corner Pads Allowed
Corner pads are allowed for all available pitches before and after touch down. However, reduced overtravel may be
required, as well as a slight adjustment of the probe in the scrub direction to avoid collision with the quadrant probes.
75 µ
pitch
80 µ
pitch
100 µ
pitch
125 µ
pitch
150 µ
pitch
200 µ
pitch
250 µ
pitch
GSG
layout
110GHz
GS or SG
layout
67 GHz
N
OTE
InfinityQuad probes are fully quadrant compatible when used exclusively with the same
pitch. For quadrant compatibility with other types of pitches or probes, please contact Cas-
cade Microtech.
Quadrant capability: scope view